Application scenarios: distributed energy station, industrial and commercial energy storage, optical storage and charging integration, microgrid, power grid station area energy storage, emergency power supply system
Flexible and light
Flexible configuration, can realize multi-machine parallel, realize the building block of energy storage power station, effectively save the floor area.
Safe and stable
Full liquid cooling design; Battery pack IP67 or above high protection grade; Multistage fuse protection for battery pack, high pressure box and bus cabinet.
Single Cluster management
No parallel on the DC side, eliminating the "short board" effect in the process of recharging and discharging, truly fine management, and effectively improving the consistency of operation.
Intelligent and friendly
Professional cloud platform management team, remote monitoring, accurate fault location easy to establish data sharing with each cloud platform; With mobile phone side calculation and operation small program, truly user-friendly.
Voltage range | AC380V±10%50/60Hz |
Maximum current | 167A |
Pattern voltage | 380V |
Rated charging and discharging power | 100 KW |
Maximum charge and discharge power | 110 KW |
Battery type | 280Ah ferric phosphate battery 1P260S |
Number of system string and union | 832V |
Rated voltage | 232.96kwh |
Available capacity | 0~95% |
DOD | 8000 |
Life span | @25土5°C;0.5C, 95%DOD,70%EOL |
Maximum efficiency of system | >90% |
Cut peaks and fill valleys | Be equipped with |
Remote scheduling | Be equipped with |
Size (Width * depth * height) | 1300*1300*2250mm |
Weight | 2800kg |
Ambient temperature range | -20°C~+50°C |
Relative humidity | 0~95% |
Class of protection | IP54(Cabinet level protection) liquid cooling |
Cooling mode | ADAPTS to the mobile operation small program |
APP | Modbus TCP/IP |
Communication mode | RS485/4G |